The Cellular Fibronectin (CFN) BioAssay ELISA Kit (Human) is a quantitative sandwich assay for the detection of CFN in human serum,plasma,tissue homogenates and other biological fluids.Detection Range:1.563-100ng/mlSensitivity:<0.938ng/mlPrecision: Intra-Assay CV: <8%Inter-Assay CV: <10%Assay Principle:The microtiter plate provided in this kit has been pre-coated with an antibody specific to CFN . Standards and samples are added to the appropriate microtiter plate wells followed by a biotin-conjugated antibody specific to CFN. Streptavidin conjugated to horseradish peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added,only those wells that contain CFN,biotin-conjugated antibody and enzyme-conjugated streptavidin complex will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulfuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of CFN in the sample is then determined by comparing the O.D. of the sample to the standard curve.Kit Components:369815A: Microtiter Strips,8x12 wells.369815B: Standard,2 vials369815C: Sample/Standard Dilution Buffer,1x20ml369815D: Antibody-Biotin (Concentrated),1x120ul369815E: Antibody Dilution Buffer,1x10ml369815F: Streptavidin-HRP Conjugate (SABC),1x120ul369815G: SABC Dilution Buffer,1x10ml369815H: TMB Substrate,1x10ml369815J: Stop Solution,1x10ml369815K: Wash Buffer (25X),1x30mlStorage and Stability:Store unopened 369815A at 4ºC; store at -20ºC once opened. Store unopened 369815B at 4°C; once reconstituted store at 4°C for up to 12 hours or at -20°C for up to 48 hours. Store 369815F and 369815H protected from light at 4°C. Store all other components at 4°C. Kit is stable for 6 months after receipt. For maximum recovery of product,centrifuge the original vials after thawing and prior to removing the cap.Assay Summary:1. Wash plate 2 times before adding standards,samples and control (zero) to wells.2. Add 100ul standard or sample to each well and incubate for 90 minutes at 37°C 3. Aspirate the liquid and wash plate 3 times.3. Add 100ul Antibody-Biotin working solution to each well and incubate for 60 minutes at 37°C4. Aspirate the liquid and wash plate 3 times.5. Add 100ul SABC working solution to each well. Incubate for 30 minutes at 37°C6. Aspirate the liquid and wash plate 5 times.7. Add 90ul TMB substrate. Incubate 15-30 minutes at 37°C8. Add 50ul Stop Solution. Read at 450nm immediately.9. Calculate results.